Row PDUs & RPPs
Row-level power distribution between facility power and the rack row: floor-standing PDUs with an integral step-down or isolation transformer (480 V to 415Y/240 V or 208Y/120 V), and remote power panels that distribute without transforming. Compare kVA capacity, input and output voltage, output current rating, and panelboard configuration across every tracked manufacturer.
88 products · 4 vendors · 23 specs tracked
All row pdus products
| Product | Type | Capacity | Input voltage | Output voltage | Output current | Updated |
|---|---|---|---|---|---|---|
| Anord MardixPOWER DISTRIBUTION UNIT | floor_pdu | - | - | 100A to 1250A | Aug 6 | |
| Anord MardixREMOTE POWER PANEL | rpp | - | - | - | 400 | Aug 6 |
| APCGRPPIP2X84 | rpp | - | 240 | 240 | - | Aug 6 |
| APCGRPPIP2X89 | rpp | - | 240 | 240 | - | Aug 6 |
| APCGRPPNF84 | rpp | - | 480 | 480 | - | Aug 6 |
| APCGRPPNF89 | rpp | - | 480 | 480 | - | Aug 6 |
| APCGRPPNQ84 | rpp | - | 240 | 240 | - | Aug 6 |
| APCGRPPNQ89 | rpp | - | 240 | 240 | - | Aug 6 |
| APCPD150G6F | - | 144 | 480 | 208 | 416 | Aug 6 |
| APCPD40F6FK1-M | - | - | 208 | 208 | 139 | Aug 6 |
| APCPD40G6FK1-M | - | - | 480 | 208 | 139 | Aug 6 |
| APCPD60F6FK1 | - | - | 208 | 208 | 167 | Aug 6 |
| APCPD60G6FK1 | - | - | 480 | 208 | 167 | Aug 6 |
| APCPD60L6FK1 | - | - | 600 | 208 | 167 | Aug 6 |
| APCPD80F6FK1-M | - | 80 | 208 | 208 | 277.5 | Aug 6 |
| APCPD80G6FK1-M | - | 80 | 480 | 208 | 277.5 | Aug 6 |
| APCPD80L6FK1-M | - | 80 | 600 | 208 | 277.5 | Aug 6 |
| APCPDPB150G6F | floor_pdu | - | 480 | 208 | - | Aug 6 |
| APCPDPM100F-M | - | 100 | 208 | 208 | 278 | Aug 6 |
| APCPDPM100F6F-M | floor_pdu | 100 | 208 | 208 | 278 | Aug 6 |
| APCPDPM100G6F-M | floor_pdu | 100 | 480 | 208 | 278 | Aug 6 |
| APCPDPM100L6F-M | floor_pdu | 100 | 600 | 208 | 127 | Aug 6 |
| APCPDPM144F | rpp | - | 208 | 208 | 400 | Aug 6 |
| APCPDPM150G6F | floor_pdu | 144 | 480 | 208 | - | Aug 6 |
| APCPDPM150L6F | floor_pdu | 144 | 600 | 208 | - | Aug 6 |
| APCPDPM175G6H | floor_pdu | 175 | 480 | 415 | - | Aug 6 |
| APCPDPM277H | rpp | - | 400 | - | 400 | Aug 6 |
| APCPDPM288G6H | - | 266 | 480 | - | 370 | Aug 6 |
| APCPDPM72F-5U | - | 72 | 208 | - | 200 | Aug 6 |
| APCPDRDPF10U-R | - | 28.8 | 208 | 208 | - | Aug 6 |
| APCPDRPPNX10 | distribution_cabinet | - | 208 | 208 | - | Aug 6 |
| APCPDRPPNX10-M | distribution_cabinet | - | 208 | 208 | - | Aug 6 |
| APCPDRPPNX14-M | distribution_cabinet | - | 208 | 208 | - | Aug 6 |
| APCPMM100 | - | - | - | 208 | - | Aug 6 |
| APCPMM1000-CUB | floor_pdu | - | 480 | - | - | Aug 6 |
| APCPMM125 | - | - | - | 208 | - | Aug 6 |
| APCPMM150 | - | - | - | 208 | - | Aug 6 |
| APCPMM200 | - | - | 480 | 208 | - | Aug 6 |
| APCPMM225 | - | - | - | 208 | - | Aug 6 |
| APCPMM30 | - | - | - | 208 | - | Aug 6 |
| APCPMM300 | - | - | 480 | 208 | - | Aug 6 |
| APCPMM400-ALA | floor_pdu | - | 480 | - | - | Aug 6 |
| APCPMM400-ALAX | floor_pdu | - | 480 | - | - | Aug 6 |
| APCPMM400-CUB | floor_pdu | - | 480 | 208 | - | Aug 6 |
| APCPMM50 | - | - | - | 208 | - | Aug 6 |
| APCPMM500-ALA | floor_pdu | - | 480 | - | - | Aug 6 |
| APCPMM500-ALAX | floor_pdu | - | 480 | - | - | Aug 6 |
| APCPMM500-CUB | floor_pdu | - | 480 | 208 | - | Aug 6 |
| APCPMM75 | - | - | - | 208 | - | Aug 6 |
| Eaton164001118 | rpp | - | - | - | - | Aug 7 |
| EatonEATON-PDI-MODULAR-COMPACT-RPP | rpp | - | - | - | - | Aug 7 |
| EatonMCP21206 | - | - | 208 | - | - | Aug 7 |
| EatonMCP65742 | rpp | - | - | - | - | Aug 7 |
| EatonMCRPP | rpp | - | - | - | - | Aug 7 |
| EatonMCRPP MODEL C | - | - | - | - | - | Aug 7 |
| EatonMCRPP MODEL-A | rpp | - | - | - | - | Aug 7 |
| EatonMCRPP MODEL-B | - | - | - | - | - | Aug 7 |
| EatonMCRPP MODEL-D | - | - | 208 | - | - | Aug 7 |
| EatonMCRPP-225 | rpp | - | - | - | - | Aug 7 |
| EatonMCRPP-400 | rpp | - | - | - | - | Aug 7 |
| EatonMODULAR COMPACT RPP | rpp | - | - | - | - | Aug 7 |
| EatonNQ CRPP | rpp | - | - | - | - | Aug 7 |
| EatonPDR | - | - | - | - | - | Aug 7 |
| EatonPLATFORM PDU (200-300 KVA) | floor_pdu | - | - | - | - | Aug 7 |
| EatonPLATFORM PDU (400-500 KVA) | floor_pdu | - | - | - | - | Aug 7 |
| EatonPLATFORM PDU (UP TO 150 KVA) | floor_pdu | - | - | - | - | Aug 7 |
| EatonPOWERPAK 2 EX | floor_pdu | - | - | - | - | Aug 10 |
| EatonPOWERPAK 2 EX 300 - 625 KVA PDU | - | - | - | - | - | Aug 7 |
| EatonPOWERPAK 2 EX PDU | - | - | - | - | - | Aug 7 |
| EatonPP2 EX | floor_pdu | - | - | - | - | Aug 7 |
| EatonRACK DEPTH RPP | rpp | - | - | - | - | Aug 7 |
| EatonRACK RPP | rpp | - | - | - | - | Aug 7 |
| EatonRPP-225 | rpp | - | - | - | - | Aug 7 |
| EatonRPP-400 | rpp | - | - | - | - | Aug 7 |
| EatonRPP02FXA | rpp | - | - | - | - | Aug 7 |
| EatonRPP18286 | - | - | - | - | - | Aug 7 |
| EatonRPP18343 | rpp | - | - | - | - | Aug 7 |
| EatonRPP18675 | - | - | - | - | - | Aug 7 |
| EatonRPP18711 | - | - | - | - | - | Aug 7 |
| EatonRPP18723 | rpp | - | - | - | - | Aug 9 |
| EatonRPP18744 | - | - | - | - | 225 | Aug 7 |
| VertivLIEBERT DPM | rpp | - | - | - | - | Aug 6 |
| VertivLIEBERT PPC | - | - | - | - | - | Aug 6 |
| VertivLIEBERT RX | - | - | - | - | - | Aug 6 |
| VertivLIEBERT RXV 250 A | rpp | - | - | - | 250 | Aug 6 |
| VertivLIEBERT RXV 400 A | rpp | - | - | - | 400 | Aug 6 |
| VertivLIEBERT TFX | floor_pdu | - | - | - | - | Aug 7 |
| VertivVERTIV LIEBERT PPC PDU 400-1000 KVA | floor_pdu | - | - | - | - | Aug 7 |