Server Technology C4W36RA-GPBD2EE1 vs Server Technology C4W36RA-YCBE2FE3
Every normalized spec, side by side. Rows where the two products differ are highlighted.
Blurred values are subscriber-only. Sign in to start a free trial — 2 full pages a day — or subscribe for unlimited access.
Highlighted rows differ across the selected products. Vendors publish different spec fields, so blank cells are common. A blank cell means the field is absent from that vendor's datasheet, not necessarily from the product.
| Attribute | Server TechnologyC4W36RA-GPBD2EE1 | Server TechnologyC4W36RA-YCBE2FE3 |
|---|---|---|
| Overview | ||
| Product family | PRO4X Switched PDUs | PRO4X Switched PDUs |
| SKU | C4W36RA-GPBD2EE1 | C4W36RA-YCBE2FE3 |
| Form factor | — | Horizontal |
| Electrical | ||
| Max input (kW) | 17.3 | 8.6 |
| Input voltage (V) | 415 | 208 |
| Input amps (A) | 24 | 24 |
| Frequency (Hz) | 50/60 | 50/60 |
| Input plug | 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | NEMA L21-30P |
| Outlets | ||
| Total outlets | — | 15 |
| Monitoring | ||
| Monitoring | switched | switched |
| Per-outlet switching | ||
| Compliance | ||
| Warranty (years) | 2 | 2 |
| Other | ||
| Phase | three-phase | — |
| Product Name | PRO4X Switched PDU | Server Technology PRO4X Switched PDU |
| Branch Circuit Protection | ||
| Branch Measurement Accuracy Current | ||
| Description | — | |
| Dimensions | ||
| Input Measurement Accuracy Active Energy | ||
| Input Measurement Accuracy Active Power | ||
| Input Measurement Accuracy Apparent Energy | ||
| Input Measurement Accuracy Apparent Power | ||
| Input Measurement Accuracy Crest Factor | ||
| Input Measurement Accuracy Current Total Harmonic Distortion | ||
| Input Measurement Accuracy Gui Current | ||
| Input Measurement Accuracy Lcd Current | ||
| Input Measurement Accuracy Neutral Current | ||
| Input Measurement Accuracy Neutral Voltage | ||
| Input Measurement Accuracy Power Factor | ||
| Input Measurement Accuracy Reactive Energy | ||
| Input Measurement Accuracy Reactive Power | ||
| Input Measurement Accuracy Voltage | ||
| Input Measurement Accuracy Voltage Total Harmonic Distortion | ||
| Operating Environment | ||
| Outlet Type | ||
| Output Measurement Accuracy Active Energy | ||
| Output Measurement Accuracy Active Power | ||
| Output Measurement Accuracy Apparent Power | ||
| Output Measurement Accuracy Crest Factor | ||
| Output Measurement Accuracy Current Total Harmonic Distortio | ||
| Output Measurement Accuracy Gui Current | ||
| Output Measurement Accuracy Lcd Current | ||
| Output Measurement Accuracy Power Factor | ||
| Output Measurement Accuracy Reactive Energy | ||
| Output Measurement Accuracy Reactive Power | ||
| Output Measurement Accuracy Voltage | ||
| Output Measurement Accuracy Voltage Total Harmonic Distortio | ||
| Product Line | ||
| Quiescent Unloaded Power Draw | ||
| Storage Environment | ||
| Pdu Type | — | Switched |
| Model | — | |